← Model losses

Head-to-head comparison

openai / gpt-6-sol / xhigh / xhigh effort preferred over claude-code-cli / claude-haiku-5-5 / medium / medium effort · close win.

Primary judge: Sol 6.1, requested Low. Effective provider effort and internal attempts were not verified. A close win is still a scored preference; it does not establish a material defect.

Reviewed public evidence

Task goal

Read-only research analysis. A classifier is evaluated on1000examples, but near-duplicate records from the same customer occur in both train and test. Hyperparameters were tuned repeatedly against this testset. Accuracy is95percent, subgroup accuracy is missing, and positive prevalence will change after launch. Explain which claims remain supported and design minimal split, selection, calibration and monitoring checks for a defensible release decision. Distinguish discrimination from calibration and random-sample uncertainty from leakage. No outside sources, tools or executed-test claims. Three numbered items, under180words.

openai / gpt-6-sol / xhigh / xhigh effort answer

1. The 95% is an observed score on a contaminated, repeatedly consulted test set—not a defensible estimate of launch accuracy. Random-sample uncertainty cannot account for customer overlap or test-driven tuning. With subgroup accuracy missing and prevalence expected to change, neither subgroup performance nor future accuracy is established. Accuracy at one threshold also does not establish ranking discrimination or probability calibration.

2. Split by customer, remove cross-split near-duplicates, and use a chronological holdout if launch involves later data. Tune hyperparameters and thresholds only within group-aware training/validation; freeze the model before one evaluation on an untouched test set. Report discrimination, accuracy, subgroup counts and metrics, and uncertainty. Set acceptable performance bounds in advance; do not release if they cannot be assessed or met.

3. Fit calibration on separate, customer-disjoint data and assess predicted probabilities against outcomes overall and by subgroup. Changing prevalence can change predictive values and calibration even if ranking remains stable. After launch, monitor prevalence, labeled performance, subgroup outcomes, calibration, and drift against predefined alert and rollback thresholds.

claude-code-cli / claude-haiku-5-5 / medium / medium effort answer

1. **Supported vs. unsupported:** The 95% accuracy on 1,000 examples has a random-sampling 95% CI of roughly 93.6–96.4%, but only if the test set is an independent random sample. Customer-level near-duplicates in train and test likely inflate the estimate (leakage), and repeated tuning on this test set adds optimistic selection bias. Neither is fixed by more samples. Accuracy also depends on the threshold and prevalence, so it does not establish discrimination or calibration. Subgroup fairness and post-launch performance are unsupported.

2. **Minimal pre-release checks:** Split train, validation, and test by customer ID. Tune hyperparameters only on validation (or group-CV), and keep one sealed test set used once. Add a recent or new-customer holdout. Report discrimination (AUC/PR) separately from calibration (reliability curve, Brier score, calibration slope). Report subgroup accuracy with CIs, and flag any subgroup with missing or small-n data as unverified.

3. **Release decision and monitoring:** Pre-register thresholds on the clean holdout, using the lower CI bound and calibration limits. Re-estimate calibration or threshold under the expected new prevalence before launch. Shadow-deploy, then monitor prevalence, score distribution, calibration drift, and per-subgroup metrics, with rollback triggers and a label-delay plan.

Primary judge's stated reason

B receives a slight forced preference because its calibration-data separation makes the proposed release evaluation easier to implement without evaluation reuse. Both substantially address leakage, selection bias, unsupported launch and subgroup claims, prevalence changes, and monitoring. This is not an established material quality gap; uncertainty remains about how A intended to allocate calibration data, and an independent review could reasonably prefer A's operational specificity.

This reason is the judge's assessment. No independent factual-defect finding is asserted by this record.

Battle wave: f983d574-14f7-4a53-8982-d4a8b48b575c. Pair: brp1_1c4164c03daa3d2f7dc546a5c0fa98cbe17dbc1e7b1136ca1c61fd3a8332b756. A separate independent review is required before calling a concern a verified factual defect. Judge disagreement is not recorded here.