← Model losses

Head-to-head comparison

openai / gpt-6-sol / xhigh / xhigh effort preferred over claude-code-cli / claude-opus-5-5 / high / high effort · close win.

Primary judge: Sol 6.1, requested Low. Effective provider effort and internal attempts were not verified. A close win is still a scored preference; it does not establish a material defect.

Reviewed public evidence

Task goal

Read-only research analysis. A classifier is evaluated on1000examples, but near-duplicate records from the same customer occur in both train and test. Hyperparameters were tuned repeatedly against this testset. Accuracy is95percent, subgroup accuracy is missing, and positive prevalence will change after launch. Explain which claims remain supported and design minimal split, selection, calibration and monitoring checks for a defensible release decision. Distinguish discrimination from calibration and random-sample uncertainty from leakage. No outside sources, tools or executed-test claims. Three numbered items, under180words.

openai / gpt-6-sol / xhigh / xhigh effort answer

1. The 95% is an observed score on a contaminated, repeatedly consulted test set—not a defensible estimate of launch accuracy. Random-sample uncertainty cannot account for customer overlap or test-driven tuning. With subgroup accuracy missing and prevalence expected to change, neither subgroup performance nor future accuracy is established. Accuracy at one threshold also does not establish ranking discrimination or probability calibration.

2. Split by customer, remove cross-split near-duplicates, and use a chronological holdout if launch involves later data. Tune hyperparameters and thresholds only within group-aware training/validation; freeze the model before one evaluation on an untouched test set. Report discrimination, accuracy, subgroup counts and metrics, and uncertainty. Set acceptable performance bounds in advance; do not release if they cannot be assessed or met.

3. Fit calibration on separate, customer-disjoint data and assess predicted probabilities against outcomes overall and by subgroup. Changing prevalence can change predictive values and calibration even if ranking remains stable. After launch, monitor prevalence, labeled performance, subgroup outcomes, calibration, and drift against predefined alert and rollback thresholds.

claude-code-cli / claude-opus-5-5 / high / high effort answer

1. **What is still supported:** Very little. The 95% figure on 1,000 examples is biased upward, for two reasons:
   - Near-duplicates from the same customer appear in both train and test, so the model can score well by recognizing customers.
   - Repeated tuning against this test set has overfit it.

   Random-sample uncertainty is a separate issue. Its standard error is about 0.7%, roughly ±1.4 points. That interval assumes independent, untouched examples. Leakage is a systematic bias, and a wider interval cannot correct it. Accuracy alone says nothing about ranking quality, calibration, subgroups or the majority-class baseline.

2. **Split and selection:** Deduplicate the records, then split by customer so no customer appears in more than one partition. Tune only with grouped cross-validation or a separate validation set. Freeze the model, threshold and metrics, then score a fresh grouped holdout once. Report accuracy and discrimination (AUROC, PR-AUC) with confidence intervals, overall and for prespecified, adequately sized subgroups.

3. **Calibration and monitoring:** Check calibration on the holdout separately, using reliability curves, Brier score and calibration slope/intercept. AUROC does not depend on prevalence, but calibration and PPV (precision) do. So recompute PPV and the threshold at the expected new prevalence, and plan a prior-shift intercept recalibration. After launch, monitor:
   - input drift and predicted-positive rate;
   - calibration once delayed labels arrive;
   - subgroup errors, with predefined rollback triggers.

Primary judge's stated reason

A earns a slight, forced preference because its account better preserves what the evidence establishes without presenting suspected optimism as an observed effect. B's concrete diagnostics remain useful. This is not an established material quality gap, and an independent review could reasonably prefer B's specificity.

This reason is the judge's assessment. No independent factual-defect finding is asserted by this record.

Battle wave: f983d574-14f7-4a53-8982-d4a8b48b575c. Pair: brp1_5dae796fae8efbaef376fde3a4935166da9c12e92cbc73990aa20a95393c7205. A separate independent review is required before calling a concern a verified factual defect. Judge disagreement is not recorded here.