claude-code-cli / claude-haiku-5-5 / medium / medium effort preferred over claude-code-cli / claude-sonnet-5-5 / high / high effort · close win.
Primary judge: Sol 6.1, requested Low. Effective provider effort and internal attempts were not verified. A close win is still a scored preference; it does not establish a material defect.
Reviewed public evidence
Task goal
Read-only research analysis. A classifier is evaluated on1000examples, but near-duplicate records from the same customer occur in both train and test. Hyperparameters were tuned repeatedly against this testset. Accuracy is95percent, subgroup accuracy is missing, and positive prevalence will change after launch. Explain which claims remain supported and design minimal split, selection, calibration and monitoring checks for a defensible release decision. Distinguish discrimination from calibration and random-sample uncertainty from leakage. No outside sources, tools or executed-test claims. Three numbered items, under180words.
claude-code-cli / claude-haiku-5-5 / medium / medium effort answer
1. **Supported vs. unsupported:** The 95% accuracy on 1,000 examples has a random-sampling 95% CI of roughly 93.6–96.4%, but only if the test set is an independent random sample. Customer-level near-duplicates in train and test likely inflate the estimate (leakage), and repeated tuning on this test set adds optimistic selection bias. Neither is fixed by more samples. Accuracy also depends on the threshold and prevalence, so it does not establish discrimination or calibration. Subgroup fairness and post-launch performance are unsupported.
2. **Minimal pre-release checks:** Split train, validation, and test by customer ID. Tune hyperparameters only on validation (or group-CV), and keep one sealed test set used once. Add a recent or new-customer holdout. Report discrimination (AUC/PR) separately from calibration (reliability curve, Brier score, calibration slope). Report subgroup accuracy with CIs, and flag any subgroup with missing or small-n data as unverified.
3. **Release decision and monitoring:** Pre-register thresholds on the clean holdout, using the lower CI bound and calibration limits. Re-estimate calibration or threshold under the expected new prevalence before launch. Shadow-deploy, then monitor prevalence, score distribution, calibration drift, and per-subgroup metrics, with rollback triggers and a label-delay plan.
claude-code-cli / claude-sonnet-5-5 / high / high effort answer
1. **Supported claims:** 95% is only an optimistic, in-sample-like estimate. Near-duplicate customers across train and test, plus repeated tuning on the test set, create leakage and selection bias. A binomial interval on n=1000 (about ±1.4 points) covers random sampling error only, not that bias. Not supported: generalization to new customers, subgroup performance, calibration, and performance under a new prevalence. Accuracy also hides discrimination, which AUC or PR measures, and it shifts with prevalence.
2. **Split and selection:** Re-split by customer ID (grouped) and deduplicate near-duplicates. Tune with grouped cross-validation on training data only. Then evaluate once on a fresh, untouched, customer-disjoint holdout. Report the gap between the old and new estimates as the leakage-plus-selection effect. Report subgroup sensitivity, specificity, and AUC with grouped bootstrap intervals, resampling by customer.
3. **Calibration and monitoring:** Check reliability curves, calibration intercept/slope, and Brier score on the clean holdout. Reweight or simulate across plausible prevalences, and set thresholds by cost. After launch, track prevalence, score drift, calibration on delayed labels, and subgroup metrics, with rollback triggers.
*This was direct analysis; no team tools were used.*
Primary judge's stated reason
A receives a slight forced preference because its interpretation of leakage is more cautious, reducing the risk of presenting an observational performance difference as an isolated bias estimate. This is not an established material quality difference; B's more explicit grouped uncertainty analysis could reasonably support an independent review preferring B.
This reason is the judge's assessment. No independent factual-defect finding is asserted by this record.
Battle wave: f983d574-14f7-4a53-8982-d4a8b48b575c. Pair: brp1_6097a59bdead955696bcf1999ad7813e4ef4bee1c40b0e599967edc83a39a35b. A separate independent review is required before calling a concern a verified factual defect. Judge disagreement is not recorded here.