← Model losses

Head-to-head comparison

openai / gpt-6-luna / high / high effort preferred over claude-code-cli / claude-haiku-5-5 / medium / medium effort · close win.

Primary judge: Sol 6.1, requested Low. Effective provider effort and internal attempts were not verified. A close win is still a scored preference; it does not establish a material defect.

Reviewed public evidence

Task goal

Read-only research analysis. A classifier is evaluated on1000examples, but near-duplicate records from the same customer occur in both train and test. Hyperparameters were tuned repeatedly against this testset. Accuracy is95percent, subgroup accuracy is missing, and positive prevalence will change after launch. Explain which claims remain supported and design minimal split, selection, calibration and monitoring checks for a defensible release decision. Distinguish discrimination from calibration and random-sample uncertainty from leakage. No outside sources, tools or executed-test claims. Three numbered items, under180words.

openai / gpt-6-luna / high / high effort answer

1. **Supported:** The observed test accuracy is 95% on the evaluated records. It does not establish performance on new customers: customer-level near-duplicates can leak across the split, and repeated test-set tuning makes that set unsuitable as an unbiased final evaluation. Accuracy alone says nothing about subgroup performance or calibration.

2. **Minimal checks:** Create customer-grouped train, validation, and untouched test splits. Tune only within training data, using grouped cross-validation; use validation for selection and calibration, and evaluate once on the test set. Report discrimination (for example, ranking performance) separately from calibration (whether predicted probabilities match observed frequencies), alongside accuracy and subgroup results. A changed positive prevalence can alter accuracy, predictive values, and calibration even if discrimination is stable.

3. **Release and monitoring:** Treat 95% as descriptive, not a release guarantee. Sampling uncertainty depends on independent representative examples; 1,000 records do not imply 1,000 independent customers, and a confidence interval cannot remedy leakage or test reuse. Before release, check performance and calibration on representative, customer-independent data. Monitor prevalence, calibration, discrimination, and subgroup outcomes after launch; define review or rollback triggers. The packet provides no subgroup, customer-count, or post-launch evidence, so release readiness remains uncertain.

claude-code-cli / claude-haiku-5-5 / medium / medium effort answer

1. **Supported vs. unsupported:** The 95% accuracy on 1,000 examples has a random-sampling 95% CI of roughly 93.6–96.4%, but only if the test set is an independent random sample. Customer-level near-duplicates in train and test likely inflate the estimate (leakage), and repeated tuning on this test set adds optimistic selection bias. Neither is fixed by more samples. Accuracy also depends on the threshold and prevalence, so it does not establish discrimination or calibration. Subgroup fairness and post-launch performance are unsupported.

2. **Minimal pre-release checks:** Split train, validation, and test by customer ID. Tune hyperparameters only on validation (or group-CV), and keep one sealed test set used once. Add a recent or new-customer holdout. Report discrimination (AUC/PR) separately from calibration (reliability curve, Brier score, calibration slope). Report subgroup accuracy with CIs, and flag any subgroup with missing or small-n data as unverified.

3. **Release decision and monitoring:** Pre-register thresholds on the clean holdout, using the lower CI bound and calibration limits. Re-estimate calibration or threshold under the expected new prevalence before launch. Shadow-deploy, then monitor prevalence, score distribution, calibration drift, and per-subgroup metrics, with rollback triggers and a label-delay plan.

Primary judge's stated reason

B receives a forced, weak preference because its descriptive interpretation of the observed accuracy and explicit customer-level uncertainty explanation make the limits of release evidence slightly clearer. A's more operational metrics and monitoring details are substantial counterevidence. This is not an established material quality gap, and an independent review could reasonably reject the preference.

This reason is the judge's assessment. No independent factual-defect finding is asserted by this record.

Battle wave: f983d574-14f7-4a53-8982-d4a8b48b575c. Pair: brp1_815635cfc2a56d54faa948749190da6a17a789e1e802d197c630f700df481b29. A separate independent review is required before calling a concern a verified factual defect. Judge disagreement is not recorded here.